-40%

AND Weighing FX-1200iN Legal For Trade Class II Precision Balance1220 x 0.01 g

$ 425.04

Availability: 11 in stock
  • Condition: New
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Item must be returned within: 30 Days
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Brand: AND Weighing
  • MPN: FX-1200iN
  • Return shipping will be paid by: Buyer

    Description

    ScalesGalore
    4802 Glenwood Rd.
    Brooklyn, NY 11234
    AND Weighing FX-1200iN Legal For Trade Class II Precision Balance,1220 x 0.01 g
    A&D’s FX-i Series entry level precision balance is a full-featured 0.01g to 1mg resolution balance at a very affordable price. The patented Compact Super Hybrid Sensor is at the heart of this unit and provides fast, one-second weighing response time
    A&D’s FX-i Series entry level precision balance is a full-featured 0.01g to 1mg resolution balance at a very affordable price. The patented Compact Super Hybrid Sensor is at the heart of this unit and provides fast, one-second weighing response time.
    The FX-i also contains a specially designed internal shock absorber that offers protection from the adverse effects of vertical or transverse overloading. Legal-for-trade models (NTEP and Measurement Canada) are also available.
    Statistical Calculation Function
    The statistical values Sum, Maximum, Minimum,Range, Standard Deviation, Number of Data,and Coeffi cient of Variation can be displayedor output.
    Comparator Function
    Easy to compare weighing results by setting HI limit and LO limit to display HI,OK,LO indicator.
    ACAI – Automatic Counting Accuracy Improvement
    This counting function recalculates the average weight each time a sample is added to eliminate errors caused by variations in unit weight.
    Percent Mode Function
    A sample can be registered as 100% and the weight of another sample can be compared as a percentage
    Animal Weighing Function
    The HOLD function enables freezing of weighing data for animal weighing applications and an ANIMAL indicator appears on the display.
    Underhook
    The underhook allows for measurement of magnetic materials and density measurements in air and water
    Standard RS-232C Interface
    Incorporates bi-directional communication with a PC, printer or other peripheral devices.
    GLP/GMP/GCP/ISO Compliant
    In accordance with GLP and LIMS regulations the balance ID number and calibration data can be printed out using A&D’s AD-8121B or a PC.
    Auto Power OFF Function
    The display switches OFF automatically when the balance is inactive for 10 minutes as a power-saving tool.
    Built-in Rechargeable Battery (FXi-09)
    An optional Ni-MH rechargeable battery pack can be fitted into the FX-i series for use without AC power and for mobile applications (10 hours charging time for 8 hours operation).
    Model
    FX-1200i
    Capacity X Readability
    1220 g x 0.01g
    43.0 x 0.0005 oz
    2.68 x 0.00005 lb
    2 lb, 11.30 oz x 0.01 oz
    39.2 x 0.0005 ozt
    6100 x 0.05 ct
    786 x 0.01 dwt
    18827 x 0.2 GN
    Legal For Trade
    Model
    Yes
    NTEP Class II - NTEP CofC #08-045A2
    NTEP
    Capacity X Readability
    1220 g x 0.1g
    Pan Size
    Ø 5.91”
    Units of Measurement
    g, pcs, %, oz, lb, suit weighing environment conditions. fi tted into the FX-i series for use without AC power and lb-oz, ozt, ct, mom, dwt, GN, tl, tol, mes and MLT
    Counting Mode
    Min. Unit Mass 0.01g
    # of Samples 5, 10, 25, 50 or 100 pieces
    Percent Mode
    Min. 100% Ref. Mass 1.0g
    Min. 100% Display 0.01%, 0.1%, 1% (depends on the reference mass stored)
    Repeatability (Std. Deviation
    0.01g
    Linearity
    ±0.02g
    Stabilization Time (typically set at FAST)
    Approx. 1 second
    Sensitivity Drift
    ±2ppm / °C (10°C to 30°C)
    Operating Temp
    5°C to 40°C (41°F to 104°F), 85% RH or less (No condensation)
    Display Type
    Vacuum Fluorescent Display (VFD)
    Display Refresh Rate
    5 times / second, 10 times / second or 20 times / second
    Std. Serial Interface
    RS-232C Interface
    Weighing Pan
    150mm
    External Calibration
    1000g
    500g
    AC Adaptor
    Confirm that the adaptor type is correct for the local voltage and power receptacle
    Power Consumption
    Approx. 11VA (supplied to the AC Adaptor)
    External Dimensions
    193 (W) x 262.5 (D) x 84.5 (H) mm
    Net Weight
    Approx. 2.5kg
    ScalesGalore 4802 Glenwood Rd., Brooklyn, NY 11234